12V DC Multifunction Self-lock Relay PLC Cycle Timer Module Delay Time Switch
FRM01 multifunction relay control module, designed specifically for a variety of users with different needs, the use of micro-controller as the master unit, preset 18 kinds of functions, and can be based on user needs, customize and add other specific functions.
Power relay module using genuine quality, high-voltage power transistor, red, blue signal lights, military-grade double-sided PCB board, cloth board to consider a comprehensive, stable performance, can be widely used in a variety of power control types of occasions.
Features:
(1) new upgrade to version 2.0, the module features the eight kinds before, increased to 18 kinds, to meet the needs of more applications;
(2) increase the supply anti-reverse function, and does not take the wrong power supply is damaged module;
(3) the use of top-quality high-voltage power supply modules, discrete power supply before replacing the system more stable and reliable;
(4) increased 0.1 seconds timing, timing accuracy from the previous 0.1 seconds, upgrade to 0.01 seconds;
(5) Increase automatic power saving feature, users can independently set.
1, the module function:
Users can display the key and select the following 18 kinds of functions in one, you can set and save function parameters, you can also view the parameters of the current function of the time parameter sets the minimum 0.1 seconds adjustable accuracy better than 0.01 seconds, with regard to the specific Set operating instructions, can be obtained from vendors.
Tips: Function 1-8 start at power on their own, functional 9-18 need high pulse signal (high duration shorter than 20ms, the same applies hereinafter) is triggered to start.
Function 1:
Timing Pick: After power-up, the time delay relay T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interfaces to a high level pulse signal, repeat the above functions;
Function 2:
Timing off: When the power relay, time delay relay disconnected T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interfaces to a high level pulse signal, repeat the above functions;
Function 3:
Re-timed pull off: After power relay to not pull, the delay time T1 reaches relay; pull off the relay T2 arrives, the delay time T1 and T2 in 0.1 seconds -270 hours adjustable from an interface to CH1 High pulse signal, repeat the above functions;
Function 4:
Then pull off the timing: After power, immediately pull the relay, the relay off after the delay time T1 arrive; arrive after disconnecting relay time T2, -270 hour in 0.1 seconds delay time between T1 and T2 Adjustable, CH1 interfaces to a high level pulse signal, repeat the above functions;
Function 5:
Infinite loop timing mode 1: After power relay to not pull, the delay time T1 reaches relay; pull off the relay T2 arrives, and then repeat the above condition, the delay time T1 and T2 at 0.1 Adjustable seconds between -270 hours, to a high level pulse signal CH1 interface, you can restart the above functions;
Function 6:
Infinite Loop Timing Mode 2: After power, immediately pull the relay delay time T1 reaches the relay off; arrive after disconnecting relay time T2, and then repeat the above condition, the delay time T1 and T2 in 0.1 seconds adjustable between -270 hours, to a high level pulse signal CH1 interface, you can restart the above functions;
Function 7:
Finite loop timing mode 1: Based on the function 5, increasing the number of cycles feature, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable, NX cycles adjustable between 1-9999 times, the interface to CH1 a high level pulse signal, these functions can be re-started;
Function 8:
Finite loop timing mode 2: 6 function on the basis of increased functionality cycles, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable, NX cycles adjustable between 1-9999 times, the interface to CH1 a high level pulse signal, these functions can be re-started;
Function 9:
Latching relay modes: CH1 interfaces to relay a high level pulse signal, the relay, to give a high level pulse signal relay disconnected.
Function 10:
Trigger relay modes: CH1 interfaces to a high signal relay, relay, high disappear, relay disconnected.
Function 11:
Pull trigger timing: After power relay does not act, CH1 interfaces to a high level pulse signal, the time delay relay T1, T1 in adjustable between 0.1 seconds -270 hours, a high-level interface to repeat to CH1 pulse signal, repeat the above function;
Function 12:
Trigger timing off: After power relay does not act, a high-level interfaces to CH1 pulse signal relay, the relay off delay time T1, T1 between 0.1 seconds -270 hours adjustable, repeat to CH1 Interface a high level pulse signal, repeat the above functions;
Function 13:
Pull the trigger and then disconnect the timing: After power relay does not act, the interface to a high level pulse signal CH1, arrived after the delay time T1 relay; pull off relay arrives after T2, T1 and delay time T2 is adjustable between 0.1 seconds -270 hours, repeat the interface to a high level pulse signal CH1, repeat the above functions;
Function 14:
Disconnect and then pull trigger timing: After power relay does not act, the interface to a high level pulse signal CH1, immediately pull the relay, the relay off after the delay time T1 arrive; arrive after disconnecting relay time T2, delay time between T1 and T2 -270 hours adjustable 0.1 seconds, repeat the interface to a high level pulse signal CH1, repeat the above function;
Function 15:
Infinite loop timing mode 1: After power relay does not act, give a high level pulse signal CH1 interfaces, the delay time T1 reaches relay; pull the relay off time T2 arrive, and then repeat the above state, the extension When the time between T1 and T2 -270 hours adjustable 0.1 seconds, repeat the interface to a high level pulse signal CH1, the above function can be restarted;
Function 16:
Infinite Loop Timing Mode 2: After power relay does not act, CH1 interfaces to a high level pulse signal, immediately pull the relay, the relay off after the delay time T1 arrive; break time T2 after reaching relay, then Repeat the above state, the delay time between T1 and T2 -270 hours adjustable 0.1 seconds, repeat the interface to a high level pulse signal CH1, the above function can be restarted;
Function 17:
Finite loop timing mode 1: 15 on the basis of functionality, increasing the number of cycles feature, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable, NX cycles adjustable between 1-9999 times, repeating to CH1 interface to a high pulse signal, you can restart the above functions;
Function 18:
Finite loop timing mode 2: 16 on the basis of functionality, increasing the number of cycles feature, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable, NX cycles adjustable between 1-9999 times, repeating to CH1 interface to a high pulse signal, you can restart the above functions;
2, module interface :
Module control terminal: 3-wire interface, all interfaces are terminal, user-friendly
1, DC +: DC power positive (with 5V, 12V and 24V modules to choose from)
2, DC-: negative DC power supply
3, CH1: input detection interfaces, active high
Relay outputs: 3-wire interface, all interfaces are terminals
1, NO: normally open relay interface, the relay before the vacant after short pull with COM1
2, COM: Common Interface Relays
3, NC: normally closed relay interface COM1 relay shorted before and after the pull-vacant
Load capacity: normally open port maximum load capacity: DC 0-30V/10A, AC 0-250V/10A
NC port maximum load capacity: DC 0-28V/10A, AC 0-125V/10A